CEC Accredited · Locally Owned & Operated · Serving South East & Regional QLD · Sunshine & Gold Coast Since 2013

Sigenergy

Sigenergy SigenStor

Stackable energy storage with the Sigen Energy Controller, Sigen Battery and EV DC Charging Module. Full datasheet specifications for single phase 3.0–6.0 kW and three phase 5.0–25.0 kW.

Sigenergy SigenStor energy controller with stacked Sigen battery modules

Products › Sigenergy SigenStor

Sigenergy SigenStor energy controller with stacked Sigen battery modules

Sigenergy

SigenStor

Enjoy green energy

SigenStor is a stackable energy storage system made up of three building blocks: the Sigen Energy Controller (hybrid inverter), Sigen Battery modules (SigenStor BAT 5.0 / 8.0) and the optional Sigen EV DC Charging Module. The Energy Controller is available in single phase from 3.0 to 6.0 kW and three phase from 5.0 to 25.0 kW, with 1 to 6 battery modules per controller.

SimpleVersatileRobustIntelligent
Get a SigenStor quote →

Let numbers talk

Sigenergy is raising industry standards

15 minsStackable installation
5 minsFast commissioning
1-clickFull system diagnosis
0 msLoad-side disruption*
5 layersBattery protection
5 layersSystem protection
280 AhLong cycle-life battery cell
V2XBi-directional charging

Simple

Stackable modules install in around 15 minutes, commissioning takes around 5 minutes, and a full system diagnosis runs with one click.

Versatile

One platform covers solar, battery storage and EV charging, with V2X bi-directional charging through the Sigen EV DC Charging Module.

Robust

Five layers of battery protection, five layers of system protection and a 280 Ah long cycle-life battery cell. IP66 rated.

Intelligent

0 ms load-side disruption when the grid drops (with the Sigen Energy Gateway), plus WLAN, Fast Ethernet, RS485 and 4G/3G/2G connectivity.

Technical data

Sigen Energy Controller 3.0–6.0 kW single phase

SigenStor EC3.0 SP3.6 SP4.0 SP4.6 SP5.0 SP6.0 SP
DC input (from PV)
Max. PV power6,000 W7,360 W8,000 W9,200 W10,000 W12,000 W
Max. DC input voltage600 V
Nominal DC input voltage350 V
Start-up voltage100 V
MPPT voltage range50 ~ 550 V
Number of MPP trackers2
Number of PV strings per MPPT1
Max. input current per MPPT16 A
Max. short-circuit current per MPPT20 A
AC output (on-grid)
Nominal output power3,000 W3,680 W4,000 W4,600 W5,000 W6,000 W
Max. output apparent power3,300 VA3,680 VA4,400 VA5,000 VA5,500 VA6,600 VA
Nominal output current13.6 A16.0 A18.2 A20.9 A22.7 A27.3 A
Max. output current15.0 A16.0 A20.0 A22.7 A25.0 A30.0 A
Nominal output voltage220 / 230 / 240 V
Nominal grid frequency50 / 60 Hz
Power factor0.8 leading ~ 0.8 lagging
Total current harmonic distortionTHDi < 2%
Efficiency
Max. efficiency98.0%
European efficiency97.0%97.1%97.2%97.3%97.4%97.4%
AC output (backup)
Peak output power (10 seconds)4,500 W5,520 W6,000 W6,900 W7,500 W9,000 W
Nominal output voltage220 / 230 / 240 V
Nominal output frequency50 / 60 Hz
Power factor0.8 leading ~ 0.8 lagging
Total voltage harmonic distortionTHDv < 2%
Disruption time of backup switch¹0 ms
Battery connection
Battery module modelsSigenStor BAT 5.0 / 8.0
Number of modules per controller1 ~ 6
Battery module voltage range300 ~ 600 V
Protection
Safety protection featuresDC ground fault protection, arc fault circuit interrupter, DC reverse polarity protection, insulation monitoring, residual current monitoring, Type II DC/AC surge protection, anti-islanding protection, AC overcurrent / overvoltage / short-circuit protection
General data
Dimensions (W / H / D)700 / 300 / 245 mm
Weight18 kg
Storage temperature range-40 ~ 70 °C
Operating temperature range-30 ~ 60 °C
Relative humidity range0% ~ 95%
Max. operating altitude4,000 m
CoolingNatural convection
System ingress protection ratingIP66
CommunicationWLAN / Fast Ethernet / RS485 / Sigen CommMod (4G/3G/2G)
Standard compliance²
StandardsIEC/EN 62109-1, IEC/EN 62109-2, IEC/EN 62477, IEC/EN 61000-6-1, IEC/EN 61000-6-2

Technical data

Sigen Energy Controller 5.0–25.0 kW three phase

SigenStor EC5.0 TP6.0 TP8.0 TP10.0 TP12.0 TP15.0 TP17.0 TP20.0 TP25.0 TP
DC input (from PV)
Max. PV power (W)8,0009,60012,80016,00019,20024,00027,20032,00040,000
Max. DC input voltage1,100 V
Nominal DC input voltage600 V
Start-up voltage180 V
MPPT voltage range160 ~ 1,000 V
Number of MPP trackers234
Number of PV strings per MPPT1
Max. input current per MPPT16 A
Max. short-circuit current per MPPT20 A
AC output (on-grid)
Nominal output power (W)5,0006,0008,00010,00012,00015,00017,00020,00025,000
Max. output apparent power (VA)5,5006,6008,80011,00013,20016,50018,70022,00027,500
Nominal output current (A)7.69.112.215.218.222.825.830.438.0
Max. output current (A)8.410.013.416.720.125.128.433.441.8
Nominal output voltage380 / 400 V
Nominal grid frequency50 / 60 Hz
Power factor0.8 leading ~ 0.8 lagging
Total current harmonic distortionTHDi < 2%
Efficiency
Max. efficiency98.1%98.2%98.3%98.3%98.3%98.3%98.3%98.3%98.3%
European efficiency96.1%96.6%97.1%97.5%97.7%97.9%97.9%97.9%98.0%
AC output (backup)
Peak output power, 10 s (W)7,5009,00012,00015,00018,00022,50025,50030,00030,000
Nominal output voltage380 / 400 V
Nominal output frequency50 / 60 Hz
Power factor0.8 leading ~ 0.8 lagging
Total voltage harmonic distortionTHDv < 2%
Disruption time of backup switch¹0 ms
Battery connection
Battery module modelsSigenStor BAT 5.0 / 8.0
Number of modules per controller1 ~ 6
Battery module voltage range600 ~ 900 V
Protection
Safety protection featuresDC ground fault protection, arc fault circuit interrupter, DC reverse polarity protection, insulation monitoring, residual current monitoring, Type II DC/AC surge protection, anti-islanding protection, AC overcurrent / overvoltage / short-circuit protection
General data
Dimensions (W / H / D)700 / 300 / 260 mm
Weight36 kg
Storage temperature range-40 ~ 70 °C
Operating temperature range-30 ~ 60 °C
Relative humidity range0% ~ 95%
Max. operating altitude4,000 m
CoolingSmart air cooling
System ingress protection ratingIP66
CommunicationWLAN / Fast Ethernet / RS485 / Sigen CommMod (4G/3G/2G)
Standard compliance²
StandardsIEC/EN 62109-1, IEC/EN 62109-2, IEC/EN 61000-6-1, IEC/EN 61000-6-2

¹ Load-side disruption time. To achieve this, the Sigen Energy Gateway needs to be used together with the Sigen Energy Controller and Sigen Battery. Test conditions: in the open-circuit state of the power grid, the nominal power of the Sigen Energy Controller is higher than the total power of the home loads.
² For all standards, refer to the certificates category on the Sigenergy website.
* 0 ms load-side disruption, see note 1.

Related

Planning a SigenStor system?

We size the Energy Controller and number of battery modules to your roof, your switchboard and your evening usage.

Source: Sigenergy SigenStor datasheet. Specifications are subject to change by the manufacturer without notice; we confirm current data in every proposal.

Get a fixed-price Sigenergy SigenStor quote

Tell us how you use power and we’ll recommend the right system, sized for your home.

Scroll to Top